Radar Level Meter

Radar Level Meter PULS6X Y Series YOKOGAWA

Radar Level Meter PULS6XY Series YOKOGAWA

Radar Level Meter sends out short radar pulses toward the measured product via the antenna system. The product surface reflects the signal waves, which are then received back by the antenna system. The instrument calculates the level from the running time of the radar pulses and the entered tank height.

Advantages

Non-contact radar technology is characterized by particularly high measurement accuracy. The Radar Level Meter sends out short radar pulses toward the measured product via the antenna system. is affected neither by fluctuating product properties nor by changing process conditions such as temperature, pressure or intense dust generation. User-friendly adjustment without vessel filling and emptying save time.

Applications in liquids

Low-frequency C-band sensors PULS 65Y and 66Y are able to penetrate foam and strong condensation and are thus suitable for very difficult process conditions. Completely unaffected by vapor, gas composition, pressure, and temperature changes, the sensors reliably detect the surface of widely different products.

The compact, high-frequency K-band sensors PULS 61Y, 62Y, and 63Y are particularly suitable for applications where high accuracy is required. Excellent signal focusing is achieved even with small antennas.

Optimized for bulk solids

Due to the very good signal focusing, internal silo installations or buildup on the vessel wall do not influence the measurement. A high sensitivity electronics adapted to the requirements of bulk solids measurement enables reliable level measurement of different products up to 120 m. The measuring principle is unaffected by strong dust generation, filling noise, airflow due to pneumatic filling and temperature fluctuations.

Read More  Rosemount 5408 Level Transmitter

Technical Information

1- Model PULS 61 Y

  • Liquids in small vessels under simple process conditions

Measuring range Accuracy

  • up to 35 m, +/- 2 mm

Process fitting

  • Thread G1½, 1½ NPT, mounting strap, compression flanges from DN80, 3″

Process Temperature

  • -40 … +80 °C

Process Pressure

  • -1 … +3 bar (-100 … +300 kPa)

2- Model PULS 62 Y

  • Storage containers, reactors and process vessels with various process conditions

Measuring range Accuracy

  • up to 35 m, +/- 2 mm

Process fitting

  • Thread G1½, 1½ NPT, flanges from DN50, 2″

Process Temperature

  • -196 … +450 °C

Process Pressure

  • -1 … +160 bar (-100 … +16000 kPa)

3- Model PULS 63 Y

  • Aggressive liquids or with hygienic requirements

Measuring range Accuracy

  • up to 35 m, +/- 2 mm

Process fitting

  • Hygienic fitting, boltings, flanges from DN 50, 2″

Process temperature

  • -196 … +200 °C

Process Pressure

  • -1 … +16 bar (-100 … +1600 kPa)

4- Model PULS 65 Y

  • Liquids under simple process conditions

Measuring range Accuracy

  • up to 35 m, +/- 8 mm

Process fitting

  • Thread G1½, 1½ NPT, flanges from DN50, 2″

Process Temperature

  • -40 … +150 °C

Process Pressure

  • -1 … +16 bar (-100 … +1600 kPa)

5- Model PULS 66 Y

  • Storage tanks and process vessels with different process conditions

Measuring range Accuracy

  • up to 35 m, +/- 8 mm

Process fitting

  • flanges from DN50, 2″

Process Temperature

  • -60 … +400 °C

Process Pressure

  • -1 … +160 bar (-100 … +16000 kPa)

6- Model PULS 67 Y

  • Bulk solids for smaller to average vessel heights

Measuring range Accuracy

  • up to 15 m, +/- 2 mm
Read More  Endress+Hauser Level Measurement

Process fitting

  • Mounting strap, compression flanges from DN 80, 3″

Process Temperature

  • -40 … +80 °C

Process Pressure

  • -1 … +160 bar (-100 … +200 kPa)

7- Model PULS SR 68 Y

  • Bulk solids for average to large vessel heights

Measuring range Accuracy

  • up to 15 m, +/- 2 mm

Process fitting

  • Thread G1½, 1½ NPT, flanges from DN50, 2″

Process temperature

  • -196 … +450 °C

Process Pressure

  • -1 … +100 bar (-100 … 1000 kPa)

8- Model PULS 68 Y

  • Bulk solids for average to large vessel heights

Measuring range Accuracy

  • up to 75 m, +/- 2 mm

Process fitting

  • Thread G1½, 1½ NPT, flanges from DN50, 2″

Process temperature

  • -196 … +450 °C

Process Pressure

  • -1 … +160 bar (-100 … 16000 kPa)

9- Model PULS 69 Y

  • Bulk solids for smaller or very large vessels

Measuring range Accuracy

  • up to 120 m, +/- 5 mm

Process fitting

  • Mounting strap, compression flanges from DN 80, 3″, flanges from DN 80, 3″

Process Temperature

  • -40 … +200 °C

Process Pressure

  • -1 … +3 bar (-100 … +300 kPa)