Bourdon tube pressure gauge with switch
Bourdon tube pressure gauge with switch contacts model PGS23 WIKA
Wherever the process pressure has to be indicated locally, and, at the same time, circuits are to be made or broken, the model PGS23.1×0 switchGAUGE can be used.
Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the position of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
The set pointer can be adjusted using a removable adjustment key in the window.
Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.
The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-1) and regulations for the on-site display of the working pressure of pressure vessels.
As switch contacts magnetic snap-action contacts, reed switches, inductive contacts – for requirements to ATEX – or electronic contacts for triggering a PLC are available.
Applications
- Control and regulation of industrial processes
- Monitoring of plants and switching of electric circuits
- For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive ambience
- Process industry: Chemical, petrochemical, power plants, mining, on- and offshore, environmental technology, machine building and general plant construction
Technical Feature
Nominal size in mm
- 100
- 160
Accuracy class
- 1.0
Scale Ranges
- 0 … 0.6 to 0 … 1,600 bar or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
Steady:
- Full-scale value
Fluctuating:
- 0.9 x full-scale value
Short time:
- 1.3 x full-scale value
Permissible temperature
Ambient:
- -20 … +60 °C for unfilled instruments or instruments with silicone oil filling
Medium:
- +200 °C maximum with unfilled instruments
- +100 °C maximum with filled instruments
Temperature effect
- When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full-scale value
Process connection
- Stainless steel 316L
- Lower mount (radial) or lower back mount
- G ½ B (male), SW 22
Pressure element
- Stainless steel 316L
- C-type or helical type
Movement
- Stainless steel
Dial
- Aluminium, white, black lettering
Pointer
- Instrument pointer: Aluminium, black
- Set pointer: Red
Case
- Stainless steel
Window
- Laminated safety glass
Ring
- Bayonet ring, stainless steel
Electrical connection
- Cable terminal box
Ingress protection per IEC/EN 60529
- IP54
Switch contacts
Magnetic snap-action contact model 821
- No control unit and no power supply required
- Direct switching up to 250 V, 1 A
- Up to 4 switch contacts per measuring instrument
Inductive contact model 831
- Long service life due to non-contact sensor
- Additional control unit required (model 904.xx)
- With corresponding control unit suitable for use in zone 1 / 21 (2 GD) hazardous areas
- Low influence on the indication accuracy
- Fail-safe switching at the high switching frequency
- Insensitive to corrosion
- Up to 3 switch contacts per measuring instrument
Electronic contact model 830 E
- For direct triggering of a programmable logic controller (PLC)
- 2-wire system (option: 3-wire system)
- Long service life due to non-contact sensor
- Low influence on the indication accuracy
- Fail-safe switching at the high switching frequency
- Insensitive to corrosion
- Up to 3 switch contacts per measuring instrument
Reed switch model 851
- No control unit and no power supply required
- Direct switching up to 250 V, 1 A
- Also suitable for direct triggering of a programmable logic controller (PLC)
- Free from wear as without contact
- NS 100: Maximum two change-over contacts per measuring instrument
- NS 160: Maximum one changeover contact per measuring instrument (switching voltages AC < 50 V and DC < 75 V, switch contact not adjustable from outside)
Switching function
The switching function of the switch is indicated by index 1, 2 or 3.
- Model 8xx.1: Normally open (clockwise pointer motion)
- Model 8xx.2: Normally closed (clockwise pointer motion)
- Models 821.3 and 851.3: Change-over; one contact breaks and one contact makes simultaneously when the pointer reaches set point