Description
General Purpose Pressure Transmitters Model S-10, S-11
WIKA S-10 and S-11 pressure transmitters are precision engineered to fit most industrial pressure measurement applications.
The compact, rugged design makes these instruments suitable for applications including hydraulics and pneumatics, vacuum, test equipment, liquid level measurement, press control, compressor control, pump protection and numerous other processing and control operations.
A wide range of electrical connection and process connection options are available to meet almost any requirement.
Rugged construction The S-10 features an all-welded stainless steel measuring cell for improved media compatibility.
There are no internal soft sealing materials that may react with the media or deteriorate over time. The compact case is also made of stainless steel and is available with environmental protection ratings up to NEMA 6P / IP 68.
The S-11 transmitter features a flush diaphragm process connection. The S-11 is specifically designed for the measurement of viscous fluids or media containing solids that may clog a NPT process connection.
Flush diaphragm pressure transmitters are available in pressure ranges from 50 InWC to 8,000 psi. For high temperature media, an integral cooling element is available on the S-11.
This option increases the maximum media temperature to 300OF. Each instrument undergoes extensive quality control testing and calibration to achieve an accuracy of < 0.25% full scale.
The printed circuit boards use state-of-the-art surface mount technology and are potted in silicone gel for protection
against mechanical shock, vibration and moisture.
Each is individually temperature compensated to assure accuracy and long-term stability even when exposed to severe ambient temperature variations.
Measuring range
Gauge pressure(bar)
0 … 0.1 / 0 … 0.16 / 0 … 0.25 / 0 … 0.4 / 0 … 0.6 / 0 … 1 / 0 … 1.6 / 0 … 2.5 / 0 … 4 / 0 … 6 / 0 … 10 / 0 … 16 / 0 … 25 / 0 … 40 / 0 … 60 / 0 … 100 / 0 … 160 / 0 … 250 / 0 … 400 / 0 … 600 / 0 … 1,000
Absolute pressure(bar)
0 … 0.25 / 0 … 0.4 / 0 … 0.6 / 0 … 1 / 0 … 1.6 / 0 … 2.5 / 0 … 4 / 0 … 6 / 0 … 10 / 0 … 16 / 0 … 25 / 0.8 … 1.2
Vacuum and +/- measuring range
-0.6 … 0 / -0.4 … 0 / -0.25 … 0 / -0.16 … 0 / -0.1 … 0 / -1 … 0 / -1 … +0.6 / -1 … +1.5 / -1 … +3 / -1 … +5 / -1 … +9 / -1 … +15 / -1 … +24
Output signals
- Current (2-wire) : 4 … 20 / 20 … 4 mA
(3-wire) : 0 … 20 mA
- Voltage (3-wire) DC 0 … 10 V / 0 … 5 V / 1 … 5 V / 0.5 … 4.5 V
- ratiometric
Power Supply
4 … 20 mA, 20 … 4 mA, 0 … 20 mA, DC 0 … 5 V, DC 1 … 5 V : DC 10 … 30 V
DC 0.5 … 4.5 V ratiometric, DC 0 … 10 V: DC 4.5 … 5.5 V
Standard Thread size
EN 837
- G ¼ B
- G ½ B
DIN EN ISO 1179-2 (formerly DIN 3852-E)
- G ¼ A
- G ¼ female
ANSI/ASME B1.20.1
- ¼ NPT
- ½ NPT
SAE J514 E
- 7/16-20 UNF with 74° taper
- M20 x 1.5
- G ½ male / G ¼ female
ISO 7
- R ¼
Ingress protection
- IP65
- IP67
- IP68
Reviews